Dakota Ultrasonics ZX-5 Ultrasonic Wall Thickness Gauge Z-303-0001 with T-102-2000 Probe



Price: $ 1,750.00

Dakota Ultrasonics ZX-5 Ultrasonic Wall Thickness Gauge Z-303-0001
Calibrate to known thickness or Select Material from 8 Presets
Includes NIST-Traceable Calibration Certificate, CE-Certified
5-Year Warranty, Made in USA
Datalogging:NO | Single-Value USB Output

Total Measuring Range (depends on material and transducer/probe type)
0.025 - 36.000 inches
0.63 - 914.4 mm
Measuring Range on Steel (with standard T-102-2000 probe)
0.040 - 8.00 inches
1.00 - 199.9 mm

The Dakota Ultrasonics ZX-5 Wall Thickness GaugeZ-303-0001 accurately measures wall thickness and the extent of corrosion of all metals, ceramics, glass and most rigid plastics - from only one side! It can measure thickness up to 36 inches (915 mm), depending upon the material and transducer.

The Dakota Ultrasonics ZX-5 Ultrasonic Wall Thickness Gauge Z-303-0001 is supplied with a USB-C port for transfer of a single data value to a PC or desired data collection program. It does NOT have any built-in memory.

The ZX-5 permits the operator to select from 8 preset materials as well as program 2 custom material velocities, plus allows free adjustment of the velocity as desired and allows the end-user to calibrate to a sample of known thickness where the velocity is automatically calculated. Additionally, to optimize linearity over a wide range, the user can perform a 2 point calibration to two samples of known thickness. The optimal velocity is automatically calculated to provide the highest accuracy and linearity between the low and high calibration points.

The TI-25DLX can be used in a Single Thickness Reading mode or in a Scan mode , where the probe is dragged over a large measuring area. The minimum thickness reading recorded during the "scan" will be displayed.

The ZX-5 probe is waterproof and can be submerged in water. The gauge is impact-resistant and environmentally sealed (IP65) to provide trouble-free operation under the toughest field conditions.


line
Kit Contents
line

  • Dakota Ultrasonics ZX-5 Ultrasonic Wall Thickness Gauge Z-303-0001 With T-102-2000 Probe
  • 4 oz. bottle of coupling fluid
  • 2 AA batteries
  • NIST Traceable Calibration Certificate
  • Carrying case
  • Instruction Manual


line
Features
line

  • User can select from 8 preset materials as well as program 2 custom material velocities
  • Calibrate to a sample of known thickness which automatically calculates the optimal acoustic velocity
  • 2-Point Calibration to optimize linearity over a wide measurement range, automatically calculates the optimal acoustic velocity
  • Scan mode, 100 readings/sec. Probe is slid over a large measuring area, the minimum thickness during the "scan" will be displayed
  • Hi/Low Alarm Limits with Visual Indicator of Out of Tolerance Readings
  • Adjustable GAIN in 5 steps to fine tune the gauge for use on challenging materials or applications
  • Special-purpose probes are offered for a variety of applications (1 to 10 MHz)
  • The extruded aluminum housing is impact-resistant and environmentally sealed (IP 65)
    to provide trouble-free operation under the toughest field conditions
  • For underwater surveying, an optional 50 ft (15 meter) underwater probe/cable is available
  • High visibility LCD Display is readable in all lighting conditions and temps as low as 22 F (-30 C)
  • LCD shows Thickness Value, Velocity Setting, Gain Setting, Stability & Battery Indicators, Scan Mode, Zero, units and stored data
  • Single value data output via USB port
  • Selectable Backlight ON/OFF/AUTO
  • 5 Year Warranty, CE-Certified and Made in USA
  • User-selected Manual or Auto Zero of Transducer
  • Switch-selected units for inches or mm with Resolution of 0.001 inch (0.01 mm)
  • Includes NIST Traceable Calibration Certificate


line
Specifications
line

Total Measuring Range
(Steel)
0.025 - 36.000 inches
0.63 - 914.4 mm
(depends on material and transducer/probe type)
Measuring Range
(Steel)
0.040-8.000 inches
1.00-199.9 mm
(with standard transducer T-102-2000)
Resolution0.001 inch (0.01 mm)
Velocity Range0.0120 to .7300 in/s. 305 to 18,542 meters/sec
LCD DisplayMulti-function 7 segment 4.5 digit liquid crystal display with 0.500" digit height. Two 0.125 in14 segment fields for labels and values, and one 7 segment field for labels and values. Additional icons to indicate features and modes
Display BacklightBacklight is selectable on/off/auto, and selectable brightness (Lo, Med, Hi) options
Display Update Rate10 Hz (10 updates/sec)
Probe (Standard)1/4", 5 MHz Dual Element Transducer, actual wearface is 5/8" (17mm), p/n T-102-3300
Probes (optional)1 to 10 MHz, 3/16" up to 1 inch (custom probes available)
Probe WearfacePEEK (Polyethylethylkytone)
Cable1.2m (4ft.) waterproof cable with non-polarized, quick-disconnect connectors
Temp. LimitsAmbient: -30 to 75 C (-22 to 167 F)
Material: -20 to 100 C (0 to 200 F)
High temperature probes available
Battery Type2x AA batteries (rechargeable batteries can be used)
Battery Life45 hours continuous use
Weight308 grams (11 ounces)
Dimensions63.5 x 131.3 x 31.5 mm (2.5" x 5.17" x 1.25")
AccessoriesProbe/cable assembly, 4 oz. bottle of coupling fluid, NIST Calibration Certificate, 2 AA batteries, operating instructions, hard-plastic carrying case.
HousingExtruded aluminum body with nickel-plated aluminum end caps (gasket sealed)
Housing RatingIP65
CertificationsNIST Traceable and MIL-STD-45662A
KeypadSealed membrane that is resistant to both water and petroleum products
Seven or eight tactile-feedback keys
Pulse Repetition Frequency (PRF)200 Hz (200 pulses/sec)
To Lock SettingsWith gauge powered off, press and hold the "+" key while powering on the gauge
The LOCK icon will be illuminated on the Display
To unLock SettingsWith gauge powered off, press and hold the "-" key while powering on the gauge
The LOCK icon will turn off
GAIN AdjustmentAdjustable GAIN 5-position (VLOW, LOW, MED, HIGH, VHI), in 3dB steps, 40-52dB
Measuring ModesPulse-Echo (P-E), Differential
Output TypeUSB-C (single data value transfer, no built-in memory)
WarrantyGauge: 5 Years
Probes: 90 Days


line
Measuring Limits
line

Minimum Radius for Convex Surfaces0.350" (8.89 mm)
Minimum Radius for Concave Surfaces3" (76.2 mm)
Minimum Headroom1" (25.0 mm)
Minimum Sample Diameter0.150" (3.8 mm)
Minimum Substrate Thickness - Fna
Minimum Substrate Thickness - NFena


line
Related Products
line

TI-25-UW-50
50 Foot Underwater Probe / Cable Assembly

  • 50 Ft. Length, Waterproof Probe/Cable assembly with non-polarized, Dual-Lemo connectors
related

line

V-Block
Ultrasonic Transducer Holder

related


line
Downloads
line

Dakota Ultrasonic Dakota Ultrasonics ZX-5 Ultrasonic Wall Thickness Gauge Z-303-0001 - Data Sheet
Dakota Ultrasonics ZX-5 Ultrasonic Wall Thickness Gauge Z-303-0001 - Instruction Manual

Order Online
Check the items you would like to order then click "Add To Cart". Items typically ship within 1 Week
Product Price
Dakota Ultrasonics ZX-5 Ultrasonic Wall Thickness Gauge Z-303-0001 with T-102-2000 Probe $1,750.00
Accessories Price
T-104-1000 1/2" diameter, 2.25 MHz dual element transducer, Side In, Potted $305.00
T-104-2000 1/2" diameter, 5.0 MHz dual element transducer, Side In, Potted $305.00
T-104-0000 1/2" diameter, 1.00 MHz dual element transducer, Side In, Potted $305.00
T-102-1000 1/4" diameter, 2.25 MHz, dual element transducer, Side In, Potted $295.00
T-102-2000 1/4" diameter, 5.0 MHz, dual element transducer, Side In, Potted $295.00
A-302-6002 Protective Rubber Boot for TI / ZX Series Small Body Ultrasonic Thickness Gauges $90.00
CF12 Coupling Fluid - 12 oz / 354 ml $35.00
V-Block Transducer Holder (For 3/16" & 1/4" Transducers only), F-000-7001 $175.00
SB4 4 Step Steel Test Block, 0.1 / 0.2 / 0.4 / 0.6 inch - Uncertified, supplied in plastic case $125.00
BATT-RC4AA-WC 4-pack 2300mAh AA Ni-MH Rechargeable Batteries & Charger Kit $35.00
T-101-2000-C 3/16" diameter, 5.0 MHz dual element transducer with minimal contact area $360.00
T-042-2000 1/4" diameter, 5.0 MHz dual element transducer, High Temp 650°F / 343°C Top in, Potted $370.00
T-044-2000 1/2" diameter 5.0 MHz dual element transducer Hi-Temp (650 F/344 C), Side in, Microdot $380.00
T-212-2001 1/4" diameter, 5.0 MHz dual element transducer Hi-Temp (900 F/500 C) Top in, Microdot $445.00
T-102-3300 1/4" diameter, 7.5 MHz, dual element transducer, Side in, Potted $330.00
A-303-1002 Bluetooth Option for ZX-5, ZX-6, PZX-7 $220.00

 



 
 

Powered by Marctin Web Architecture